Skip to main content
X-VENTISO home

Searches every page and every manual, submittal and spec sheet on the site. Try XV250 weight, gas interlock or BACnet.

Hearth Appliances

Gas and solid fuel, indoors

Proven draft for every fireplace, whatever the house or the weather is doing. Short chimneys, cold starts, tight houses, long runs, and wind at the top: X-VENTISO handles the forces working against the flue.

Fuel
Gas and solid fuel
Gas ignition
Electronic ignition appliances
Control
Meridian or Controlled Power
Code
NFPA 54 · NFPA 211
Makeup air
VMASS

Two forces

Two Forces Work Against Every Chimney.

A chimney drafts because hot flue gas is lighter than the air around it. At a cold start, and again as the fire dies down, that lift is only a few Pascals, and an open fireplace can begin to spill at 3 to 4 Pa. Two forces can take that margin away.

Inside the building

A heated house in winter: air leaks out up high and in down low, around the neutral pressure plane. The fireplace sits on the negative side.
In winter the house acts like a chimney of its own, and exhaust appliances pull harder still. A 400 CFM range hood can pull a tight house negative by roughly 7 to 8 Pa. Makeup air and proven draft answer what happens inside.

Outside the building

Wind blows over a taller tree and pushes down onto the chimney top. The draft inducer at the top pushes exhaust up and away, past the wind.
Wind can sit on the outlet and push back down the flue: a gust, a taller tree, the building next door. No amount of air in the house reaches it. A draft inducer at the end of the flue run answers what happens outside.

Natural draft needs perfect conditions. A draft inducer is how a fireplace stops depending on them.

Existing fireplaces

Fixing a Fireplace That Stopped Drafting.

Many of the fireplaces we see drafted fine for years, then started to smoke. Nothing changed with the fireplace. Something changed around it.

  • Inside

    The House Got Tighter

    New windows, new doors, spray foam, or a remodel sealed the envelope the chimney used to draw from.

  • Inside

    New Exhaust

    A bigger range hood, a new dryer, bath fans, or a ventilation system now pulls against the flue.

  • Outside

    Trees Grew

    The trees around the house kept growing until they changed how wind moves across the chimney top.

  • Outside

    Something Went Up Next Door

    A new building, an addition, or a taller roof line now sends wind down onto the outlet.

An XV Series draft inducer mounts on the existing chimney top and gives the fireplace its draft back, whatever changed. Round, square, rectangular, masonry, or factory-built: we make custom adapters for any chimney size or setup. Send photos of the chimney top and the fireplace, and the flue size, and we will tell you what it takes. On gas, the appliance needs electronic ignition so the interlock can do its job.

Gas or solid fuel

Different Fires. Different Systems.

Gas and solid fuel systems compared
GasSolid fuel
ControllerMeridian: modulates to the room, interlocked with the gas controlControlled Power WBC: proven draft with a built-in audible and visual alarm
ApplianceElectronic ignition appliances, so the interlock can do its job: SIT Proflame 2, Dexen, Resideo / Honeywell, and Robertshaw ignition modulesWood-burning fireplaces
DamperSealed gas damper closes the flue when the fire is offAutomatic solid fuel damper, opened and closed from the switch
QuietWSPRDraft flue silencer and vibration dampenerVibration dampener; silencers are not used on solid fuel
Flue design targetFlow noise at or below 30 dBFlow noise at or below 35 dB
CodeNFPA 54NFPA 211

The system

One Approach, Sized to the Fireplace.

  • Draft

    XV Series

    Listed for gas, solid fuel, and grease. One draft inducer line for every fuel, sized to the flue.

  • Control

    Meridian or Controlled Power

    Proven draft, interlock or alarm, in the box with every controller package.

  • Sound

    WSPRDraft + Dampener

    The fire should be the loudest thing in the room.

  • Makeup air

    VMASS

    Replaces what exhaust appliances remove, so the chimney is not the easiest way back in.

Easy to install. Plugs into a standard 120 V outlet. Factory-wired, plug-in Molex connections from draft inducer to controller. No hardwiring. Not sure what the job needs? Send plans or call 800.642.2920 and we size it with you.

Built by fireplace makers

Engineered by People Who Build Fireplaces.

X-VENTISO is an Earthcore company. Earthcore designs, engineers, and manufactures Isokern modular masonry fireplaces, along with other fireplaces and fire features. We know what a firebox needs from a chimney because we build the firebox. That is why every X-VENTISO system is sized to the appliance, the flue, and the building together, not added on after the fact.

We work with your architect and engineer. You install.

Submit Plans
Masonry wood-burning fireplace with a stone surround and mantel, set between lit display niches.

Quiet in the room

A Fireplace You Don't Hear Running.

The fire should be the loudest thing in the room. The draft inducer sits at the end of the flue run, often 30 to 40 feet from the people below, but its sound can travel down the flue. X-VENTISO stops it in layers.

The controller runs the draft inducer only as hard as the chimney needs. The 45° upward discharge sends sound away from the house. The vibration dampener keeps motor vibration at the draft inducer. On gas installs where the room has to be truly quiet, WSPRDraft absorbs what is left in the flue.

Linear gas fireplace set into a stone wall in a modern living room.

More than one flue

Big Fireplaces Often Have More Than One Flue.

Large single-face fireplaces, see-through and double-sided units, and custom multi-sided designs often vent through two flues or more. Every flue needs proven draft, and the appliance needs to know if any one of them fails.

  • Two flues, as one

    WBC-DUO · GBC-DUO

    One controller and one MUC run both draft inducers together at one speed. If either flue faults, the MUC alarms; on gas, the appliance is shut off.

  • Two flues, independent

    Meridian DUO

    Modulates each flue on its own, each referenced to the room. For gas appliances where the two flues behave differently.

  • Three or four flues

    XV-MULTICTRL · XV-INTG

    XV-INTG links any X-VENTISO controllers on one call, one after another; on Controlled Power, XV-MULTICTRL can also share one MUC. Either way, a DUO plus a single covers three flues; two DUOs cover four.

Code

Built for NFPA 54 and NFPA 211.

Code requirements by fuel
Gas (NFPA 54)Solid fuel (NFPA 211)
Proven draftIn the boxIn the box
Appliance interlockIn the box: the appliance fires only once draft is provenSolid fuel: alarm instead
Audible and visual alarmGas: interlock insteadBuilt into the controller

Common questions

What People Ask Us.

Q.01Will I hear it?
The draft inducer sits at the end of the flue run and runs only as hard as the chimney needs. Its sound power is independently tested and published, and on gas, WSPRDraft absorbs what travels down the flue. The fire should be the loudest thing in the room.
Q.02What happens if the power goes out?
Gas: the fireplace won't light. X-VENTISO gas systems are built for electronic ignition appliances, and the interlock lets the appliance fire only once draft is proven. When power returns, the system proves draft first. It fails safe, by design. Solid fuel: if power is lost while the system is on, the controller sounds its audible and visual alarm. It does not alarm just because the house has no power while the fireplace is off. Dampers: gas dampers fail closed and seal the flue until power returns; the solid fuel damper fails open.
Q.03Can it go on an existing fireplace?
Often, yes. The chimney top, the flue size, and, on gas, an electronic ignition appliance decide it. Send photos and the flue size and we will tell you what it takes.
Q.04Is it the same draft inducer for gas and wood?
Yes. XV Series draft inducers are listed for gas, solid fuel, and grease. The controller is what changes: Meridian or Controlled Power GBC on gas, Controlled Power WBC on wood.