Skip to main content
X-VENTISO home

Searches every page and every manual, submittal and spec sheet on the site. Try XV250 weight, gas interlock or BACnet.

Outdoor Living

Covered patios, loggias, and outdoor rooms

The fire outside, without the smoke in your face. Under a roof, smoke rolls back toward the people the fire is for. A draft inducer at the end of the run gives it one way to go: out and away.

Where
Covered patios and loggias
Fuel
Gas and wood
Material
316L stainless
Discharge
45° up and away
Weather
Rain collar

Outside is all wind

Outside, the Wind Is Always Part of It.

Indoors, a chimney fights the house. Outdoors, it fights the weather. A covered patio is open on one side or more, so wind moves straight through it, and the roof above the seating area traps whatever smoke the chimney does not carry off.

Two covered patio sections. Natural draft only: wind sits on the chimney top and smoke follows the ceiling back to the seating area. With a draft inducer: exhaust goes up the flue and away from the roof, whichever way the wind blows.

See-through fireboxes are open on both faces, so wind can push across the fire from either side. Short outdoor chimneys have little natural lift to begin with. A draft inducer at the end of the run pulls the whole flue and sends exhaust away from the roofline, whichever way the wind blows.

Natural draft needs perfect conditions. Outdoors, conditions change every hour.

Built for the weather

Built to Live Outside.

  • Housing

    316L Stainless

    Housing and impeller in 316L stainless, for rain, sun, and salt air.

  • Rain

    Rain Collar

    Keeps weather out around the lower draft inducer body.

  • Controller

    NEMA 1, Under Cover

    The controller does not need conditioned space. It does need protection from rain and direct sun: mount it under cover. Need more protection? Custom enclosures are available on request.

Gas fireplace under an arched coastal loggia at dusk, with the pool and ocean beyond.
Salt air, sun, and rain: an outdoor fireplace lives in the weather.

The system

The Same Complete System as Indoors.

  • Draft

    XV Series

    Listed for gas and solid fuel. Sized to the flue and mounted at the end of the run, vertical or horizontal, wherever the design terminates.

  • Control

    Meridian or Controlled Power

    Proven draft, as indoors. On gas, interlocked with the appliance. On wood, a built-in audible and visual alarm.

  • Damper

    Top-Mount or Inline

    Top-mount dampers are built for the chimney top, where the weather is. Inline dampers install inside the chase.

  • Sound

    Vibration Dampener

    Keeps motor vibration at the draft inducer, away from the seating area.

Easy to install. Plugs into a standard 120 V outlet. Factory-wired, plug-in Molex connections from draft inducer to controller. No hardwiring. Not sure what the job needs? Send plans or call 800.642.2920 and we size it with you.

Quiet outdoors

Sound Goes Up, Not Across the Patio.

Outdoors, the draft inducer is often only a few feet above the seating area. The 45° upward discharge throws exhaust and sound up and away from the roofline instead of across it, and the controller runs the draft inducer only as hard as the fire needs.

Neighbors are part of the outdoor room too. The fire should be the loudest thing on the patio.

When is it outdoors

When Is an Outdoor Room Still Outdoors?

Outdoor gas fireplaces are certified to ANSI Z21.97 / CSA 2.41, Outdoor Decorative Gas Appliances. Installation instructions for appliances certified to that standard generally treat a space as outdoors only when its shelter is no more enclosed than one of the first three plans below.

Four plan views. Walls with no roof: outdoors. Roof with two walls: outdoors. Roof with three walls: outdoors if at least 30 percent of the perimeter is permanently open. Roof with a closable fourth side of glass or panels: indoors.

The two walls can be parallel or meet at a corner. Glass, sliding panels, and doors that can close do not count as open. Enclose the space beyond these limits and it is an indoor installation, under the National Fuel Gas Code (NFPA 54) for gas and NFPA 211 for wood. Either way, the draft is the same problem, and X-VENTISO ships the same complete system.

Code

Even Where No Code Requires It.

Outdoors, specific venting codes may not apply. X-VENTISO ships the same complete system on every job anyway: proven draft, interlocks, and alarms, in the box. An outdoor fire is still a fire, and the people around it deserve the same protection as the people inside.

What Ships in Every Box

Common questions

What People Ask Us.

Q.01Does an outdoor fireplace need a draft inducer?
Maybe not, on a calm night with a tall chimney. But we can't see the wind, the trees, or the roofline from a drawing, and outdoors those change by the hour. If the fire sits under a roof near people, proven draft is the way to stop depending on the weather.
Q.02Will it work on a see-through fireplace?
Yes. It pulls the flue from the end of the run, so it works whichever face the wind hits. See-through and multi-flue designs are sized as a system; send plans and we size it with you.
Q.03Can it go on an existing outdoor fireplace?
Often, yes. We make custom adapters for any chimney size or setup. Send photos of the chimney top and the fireplace, and the flue size, and we will tell you what it takes.
Q.04Will the neighbors hear it?
The 45° discharge sends sound up and away, and the controller runs the draft inducer only as hard as the fire needs. Its sound power is independently tested and published.
Q.05What about rain and salt air?
The housing and impeller are 316L stainless, a rain collar protects the lower body, and top-mount dampers are built for the chimney top. The controller is NEMA 1: it does not need conditioned space, but it does need to be under cover, out of rain and direct sun. For extra protection, we build custom enclosures on request.
Q.06What about a pizza oven in the outdoor kitchen?
Wood-fired ovens burn hotter and longer than a fireplace. See Pizza Ovens for how we handle them.