Two years. One visit a year keeps it.

A draft system lives on a chimney: heat, soot, creosote and weather, every season. The annual inspection is what keeps it working, and it is what keeps the warranty in force.

The whole warranty, in one line

2 Years

On every X-VENTISO product, kept by one inspection a year.

Install it per the manual and have it inspected once a year by a qualified professional. That is all it takes.

Coverage
2 years from invoice
Covers
Parts and shipping
Condition
Documented annual inspection

The terms

Two Years. Parts and Shipping.

Every X-VENTISO product carries a 2-year warranty: draft inducers, controllers, makeup air, dampers, silencers, vibration dampeners and accessories.

It is valid when the product is installed and used per its X-VENTISO installation manual and the appliance manufacturer’s instructions, and when it gets a documented annual inspection by a qualified professional.

Coverage starts on the invoice date and runs 2 years. It covers every part, and the shipping to get the replacement to the job.

One visit a year keeps the system running right and the warranty in force. Book it with your chimney service and you are set.

What it covers

Every Product. Same Two Years.

Warranty and annual inspection by product
ProductWarrantyAnnual inspection, at a glanceWhen
XV Series draft inducers2 yearsClean the vane, housing and spark arrestor; check the hinge, latches, disconnect box and Molex leadWith the chimney or flue service
Controllers: Controlled Power, Meridian, damper controls2 yearsStart-up proving test; on WBC and WBC-DUO, the power-loss alarm test and fresh CR2032 cells in the wall controlSame visit
VMASS makeup air2 yearsInspect the unit, duct, outdoor hood and pressure pickups. Filter at every HVAC filter changeWith the HVAC service
Dampers2 yearsRun open and closed; check the gas seal. Solid fuel: clean the damper whenever the chimney is sweptWith the chimney inspection
WSPRDraft flue silencers2 yearsCamera inspection from the termination or the appliance connection; clean from the roof only when neededWith the flue service
Vibration dampeners2 yearsGaskets, springs and bushings intact; nuts snugSame visit
Accessories2 yearsChecked as part of the system they serveSame visit

Full steps are in each product’s installation manual. Also inspect after any chimney fire.

The annual inspection

One Visit. Four Steps. Logged.

  1. Step 1: Book it with the chimney service

    Any qualified professional: chimney sweep, hearth installer or HVAC technician. VMASS goes with the HVAC service.

  2. Step 2: Work the checklist

    Each installation manual has an Annual Inspection Checklist. Copy it and fill it in at every visit.

  3. Step 3: Leave the copy with the owner

    The completed checklist stays with the manual at the home or building.

  4. Step 4: Log it

    Record the date, findings and technician in the service record in the manual. It is all we ask for if you ever need a part.

Why we ask for it. A draft inducer, a damper and a silencer all sit in the flue gas. Soot and creosote build up, rain and wind find their way in, and safety controls only prove what they are asked to prove. An inspection a year finds a small problem before it becomes a smoky room or a failed part.

The controllers prove draft every time the system starts. The annual visit proves the rest: the alarms sound, the dampers move, the passages are clear.

For the technician

Appliance off, controller unplugged, locked and tagged; draft inducer cool. Work the manual’s checklist top to bottom. Test the start-up proving by unplugging the damper lead at the controller; on WBC and WBC-DUO, unplug the controller with the system on: the alarm must sound.

Questions on site: 800.642.2920.

What voids it

Keeping Your Coverage.

Voids the warranty

Voids the warranty
Missing the annual inspectionCoverage depends on a documented inspection each year. Booking it with the chimney service keeps it from slipping.
Opening a controllerEvery X-VENTISO controller is sealed at the factory. No field wiring inside.
Changing the factory wiringHardwiring the draft inducer, altering the Molex plug, cutting cable lengths or moving the disconnect box. Need a different length? Call first.
A closed-top shroud without our OKSend the shroud drawing before it is built; keep our written approval with the job record.

Not covered

Not covered
Over-temperatureFlue gas above the product’s rated temperature.
Weather and waterDamage from storms, water entry or exposure.
Installation damageA miswired disconnect box; a damaged damper gas seal (replace it and find the cause).
ConsumablesBatteries and filters. They are replaced on a schedule, as the manuals describe.

Making a claim

If Something Goes Wrong, Call Us.

  1. Step 1: Call 800.642.2920

    Technical support takes the call and works the problem with you, on site if you are there.

  2. Step 2: Have the job details

    Model and serial number (on the label), the controller, the flue size, and the commissioning record.

  3. Step 3: Send the service record

    The annual inspection log from the manual. The invoice date starts the warranty, so have the invoice or order number.

  4. Step 4: We ship the part

    The replacement ships at our cost. The failed part comes back to us; we will tell you how to send it.

Documents

Where the Checklist Lives.

Every X-VENTISO controller is bench-tested before it is packed. The serial number and the tester’s initials are on every controller label.

Bring us the project. We'll find the yes.