Controlled Power

Proven draft control for gas and solid fuel

Set once, right for the application-specific chimney. The installer dials in draft inducer speed at commissioning, so it runs only as hard, and only as loud, as that chimney needs. The end user gets simple on and off from a wall switch, a remote, or a home automation contact.

XV-GBC and XV-WBC Controlled Power controllers with factory-wired Molex leads and 120 V plug-in cords.
Proves draft
Before the appliance runs
Gas
Interlocked with the gas control
Alarm
Audible and visual, built in
Wiring
Factory-wired, Molex
Power
Plugs into a 120V outlet

How it works

A fan speed control is not a draft control.

A speed control, often called a rheostat, sets how fast a fan spins. It cannot tell whether the chimney is actually drafting, and it cannot stop the appliance when it is not. Code requires both, and every X-VENTISO controller does both.

  1. 01

    Commission once

    The installer sets draft inducer speed for that specific chimney.

  2. 02

    Call

    A wall switch, remote, or automation contact turns the system on.

  3. 03

    Prove draft

    Gas: pressure-proven with the stack probe and tubing in the box. Solid fuel and grease: proven by draft inducer operation.

  4. 04

    Run or alarm

    Gas: the burner can fire only with draft proven. Solid fuel and grease: audible and visual alarm if draft fails.

Side-by-side: a speed control keeps the burner firing with a blocked flue; the X-VENTISO controller senses no draft, locks the burner out and sounds the alarm.

Quiet

Set to the chimney, not to full speed.

A draft inducer with no speed control runs flat out. With Controlled Power, the installer sets draft inducer speed on the MUC at commissioning to what that specific chimney needs. At 38 V, a typical commissioning setting, XV Series draft inducers tested 23 to 34 dB below full speed.

The rest of the system carries it the rest of the way. The draft inducer discharges 45° upward, away from the building. The vibration dampener keeps motor vibration at the draft inducer. On gas installs, the WSPRDraft flue silencer absorbs the noise that travels down the flue.

On gas, need it quieter still? Meridian modulates continuously and slows down whenever conditions allow.

Models

Choose by fuel and flue count.

  • Solid fuel and grease

    WBC

    Proves draft by draft inducer operation, with no sensor in the stack to foul in grease or creosote. Built-in audible and visual alarm, as NFPA 211 requires on solid fuel. Pairs with the automatic solid fuel damper.

  • Solid fuel and grease, two flues

    WBC-DUO

    Two draft inducers on two flues from one controller, with the same features as WBC.

  • Gas

    GBC

    Proves draft before the burner can fire. Connects directly to SIT Proflame 2, Dexen, Resideo / Honeywell, and Robertshaw ignition modules. Stack probe and tubing in the box. For full BAS integration on gas, specify Meridian.

  • Gas, two flues

    GBC-DUO

    Two draft inducers on two flues from one controller, with the same features as GBC.

One appliance, up to four flues: XV-MULTICTRL (sold separately) links two controllers of the same fuel type to one MUC. A DUO plus a single covers three flues; two DUOs cover four. Makeup air on the same call: XV-INTG adds VMASS, started last. Unusual layout? Call 800.642.2920 →

DUO

Two flues. One controller. Acting as one.

Large single-face fireplaces, see-through, double-sided, and custom multi-sided units, and ovens and commercial appliances with two flues. A second flue usually means a second draft inducer, a second control, and two systems the installer has to make agree.

WBC-DUO and GBC-DUO run both draft inducers from one controller, as one system.

X-VENTISO XV-GBC-DUO and XV-WBC-DUO controllers.
XV-GBC-DUO and XV-WBC-DUO.
  • One controller

    One MUC

    One controller and one MUC instead of two. Half the hardware at the appliance.

  • One speed

    Set once for both

    Commissioned once at the MUC. Both draft inducers run together at the same speed.

  • One call

    Start together

    One wall switch, remote, or automation contact starts both flues at the same moment.

  • One system

    Alarm and interlock

    WBC-DUO: one audible and visual alarm. GBC-DUO: one gas interlock. One system to wire and inspect.

If either flue faults, the whole system knows. The MUC alarms. On gas, the appliance is shut off. On solid fuel, it stays in alarm until the fault is resolved.

Need each flue controlled on its own? Meridian DUO modulates each flue independently, each referenced to the room. Three or four flues: two controllers on one MUC through XV-MULTICTRL.

In the box

Code compliance shouldn't be an upgrade.

IncludedWBCGBC
Plugs into a standard 120V outletIncludedIncluded
Factory-wired, plug-in Molex connectionsIncludedIncluded
Proves draftIncludedIncluded
Stack probe and pressure tubingNot includedIncluded
Gas interlock (NFPA 54)Not includedIncluded
Audible and visual alarm (NFPA 211)IncludedIncluded
Service disconnect at draft inducerIncludedIncluded
Smoke alarm (solid fuel)By buildingNot included
Listed carbon monoxide alarm (solid fuel)By buildingNot included

GFDC and SFDC are the gas and solid fuel damper controls. DUO versions carry the same features as their base controller. NFPA 211 requires the audible and visual alarm on solid fuel; GBC carries it as well. Requirement-by-requirement detail on the Code Compliance page.

The MUC

One controller. Speed and alarms built in.

Every Controlled Power package includes the MUC, the Multi Use Controller. Run and alarm lights show status at a glance, the speed slider is set once at commissioning, and the audible alarm sounds if draft fails. A service mute lets a technician silence the sound while working on the system. The alarm light stays on until the fault clears, and the mute resets on the next power cycle.

The same MUC runs both GBC and WBC, so installers learn one control for gas and solid fuel. It plugs into the controller, and turns the system on from any low-voltage contact closure: a wall switch, a remote, or an automation relay.

ConnectionMolexGoes to
Controller6-pinGBC or WBC; two controllers through XV-MULTICTRL
On / off4-pin, black leadWall switch, remote, or automation relay
Gas interlock (GBC)4-pin, black leadAppliance gas control
The MUC (Multi Use Controller) with run and alarm lights, speed slider, and service mute button.

Automation

If it can close a contact, it can run the system.

Every Controlled Power controller turns on and off from a simple low-voltage contact: a wall switch, a hearth remote, a home automation relay, or a building automation output.

Draft inducer speed is set at commissioning and stays with the controller, so no switch, app, or BAS can change it.

Need full BAS integration with status and readings on gas? Specify Meridian →

ControllerBACnet / ModbusAutomation can
XV-WBC · XV-WBC-DUONo (custom BACnet / Modbus by request)On and off by dry contact, standard
XV-GBC · XV-GBC-DUONoOn and off by dry contact, standard

Specifications

Controlled Power specifications.

SpecificationWBC / WBC-DUOGBC / GBC-DUO
FuelSolid fuel and greaseGas
FluesWBC: 1 flue · WBC-DUO: 2 fluesGBC: 1 flue · GBC-DUO: 2 flues
Draft provingDraft inducer operation, no sensor in the stackPressure, stack probe and tubing included
AlarmAudible and visual, built into the MUC (Multi Use Controller)Audible and visual, built into the MUC (Multi Use Controller)
Gas interlock-Interlocked with the appliance gas control
PowerController plugs into a standard 120V outletController plugs into a standard 120V outlet
ConnectionsMolex: draft inducer, damper, MUC (6-pin); on/off contact closure via MUC 4-pinMolex: draft inducer, damper, MUC (6-pin); on/off contact closure and gas interlock via MUC 4-pin
Low-voltage circuits (MUC, on/off input, damper)Class 2, from the controller’s internal power supplyClass 2, from the controller’s internal power supply
EnclosureFactory-sealed, NEMA 1 (indoor)Factory-sealed, NEMA 1 (indoor)
Electrical rating120 VAC, 50/60 Hz. WBC: 6.0 A · WBC-DUO: 12.0 A120 VAC, 50/60 Hz. GBC: 6.0 A · GBC-DUO: 12.0 A
ListingsUL 508 Industrial Control Panels · UL/ULC 378 Draft Equipment. ETL Listed, Intertek control no. 4007025UL 508 Industrial Control Panels · UL/ULC 378 Draft Equipment. ETL Listed, Intertek control no. 4007025
Compatible dampersAutomatic solid fuel damperGas top-mount and inline

Controllers are factory-sealed. Opening the enclosure voids the warranty.