Skip to main content
X-VENTISO home

Searches every page and every manual, submittal and spec sheet on the site. Try XV250 weight, gas interlock or BACnet.

Other Accessories

The parts that finish an installation

Rain collars, flue adapters, extension cables, the two integration devices that tie multiple systems together, ignition kits for Proflame 2 and Robertshaw, and the VMASS second heater. Each one connects to the same system and installs the same way.

X-VENTISO accessories: a stainless rain collar behind an XV-MULTICTRL integration device and an XV-INTG integration connection, each with its Molex leads.

Rain collars

Rain Collars.

Wind-driven rain does not fall straight down. It can blow sideways into the spark arrestor at the base of the draft inducer and down the chimney.

The rain collar fits around the lower body of the XV Series draft inducer and shields the spark arrestor from directional rain. A cutout in the collar fits around the factory heat shielding, so it sits tight to the draft inducer.

Recommended on every installation, and especially where the draft inducer has no shroud or other shielding around it.

Two sizes: XV-RC250 fits the XV150 and XV250; XV-RC350 fits the XV350. 316L stainless steel, the same as the draft inducer housing.

XV-RC250 rain collar installed on an XV150 draft inducer, on a rooftop chase.
XV-RC250 rain collar on an XV150.
Rain collar cutout that fits around the factory heat shielding of the XV Series draft inducer.

Flue adapters

Flue Adapters.

Every XV Series draft inducer connects to the flue through an adapter matched to the flue's make, type and size. Two families cover most jobs:

Standard adapters mount the draft inducer vertically on top of the flue.

Horizontal mount adapters are for sidewall termination: the draft inducer mounts at the end of a horizontal flue run, outside the wall. Horizontal runs are specified with an XV250 or XV350 for draft margin.

Every adapter by flue make and size: Accessory Part Numbers (PDF, opens in a new tab) (PDF, in Downloads below).

Three X-VENTISO standard flue adapters with mounting studs.

Flue Not on the List? We Build the Adapter.

Round, square, rectangular, masonry, or factory-built: we make custom adapters for any chimney size or setup. Send the flue make, model and size, or a photo of the top of the flue, and we build the adapter to fit.

Call 800.642.2920

Extension cables

Extension Cables.

Every X-VENTISO system connects with factory-made Molex cables, so a longer run is a longer cable, not field wiring. Extensions plug in at each end, the same as the standard cables.

One continuous cable is best. For long runs, custom lengths are available by request, so there is no joint along the way.

Molex extension cables
ExtensionConnectsLengths
Draft inducer (white 3-pin)Controller to draft inducer20, 50, 100 ft
Damper (white 4-pin)Controller to damper (30 ft lead standard)20, 50, 100 ft
Wall control (black 6-pin)Controller to wall control20, 50, 100 ft
Ignition (black 4-pin)Extends the 4 ft ignition cable from the wall control20, 50 ft

Every extension connection stays accessible: never in conduit or inside a closed wall. Part numbers: Accessory Part Numbers (PDF, opens in a new tab) (PDF, in Downloads below).

XV-MULTICTRL

XV-MULTICTRL Multi Unit Integration Device.

One appliance, up to four flues, one MUC. XV-MULTICTRL links two WBC or two GBC controllers to a single MUC for appliances that exhaust through more than one flue. A DUO paired with a single controller covers three flues, the most common layout. Two DUOs cover four.

One call to the MUC's 4-pin connection starts every unit together. One speed slider sets every draft inducer to the same speed, and a draft fault on either controller trips the shared alarm. Installation insert (PDF) (PDF, opens in a new tab)

Same fuel type only: WBC with WBC, GBC with GBC. Works best on flues of similar size and height. Flues that differ? Call 800.642.2920

XV-MULTICTRL multi unit integration device, black enclosure with its Molex leads.

Sold separately. For Controlled Power (WBC and GBC), which use the MUC. For Meridian, VMASS, and damper controls, see XV-INTG. Low-voltage signal device; carries no line voltage.

XV-INTG

XV-INTG Multiple System Integration Connection.

One call, every controller, in order. XV-INTG takes a single call and passes it down the line: the controller on CONTROL 1 starts first, and each one after it starts only when the one before has returned the call. The appliance lights only after the last one has. If any one fails to answer, the chain stops there and the system faults.

Works with every X-VENTISO controller. They all share the same 4-pin ignition connection, and XV-INTG plugs in between it and the ignition wiring: on Controlled Power, at the MUC. A DUO leads, then single controllers. VMASS always goes last, so makeup air is running before the appliance lights. Use it to interlock VMASS with an appliance where code requires it.

One system serves one appliance. Meridian never shares a system with Controlled Power, gas never with solid fuel, and damper controls link only with damper controls of the same fuel. VMASS can join any of them.

Each XV-INTG connects two controllers. More than two? Daisy-chain from CONTROL 2, as far as the job needs. Every lead is 3 in.; XV-IGNEXT extensions (20 or 50 ft) reach farther. Installation insert (PDF) (PDF, opens in a new tab)

XV-INTG multiple system integration connection with Control 1, Control 2 and Ignition Molex leads.

Sold separately. Two Controlled Power controllers on one wall control? Use XV-MULTICTRL. Low-voltage signal device; carries no line voltage.

Ignition kits

Ignition Kits.

XV-IGN-PFAK Proflame Automation Kit relay box with its leads and 120 V cord.

XV-IGN-PFAK Proflame Automation Kit

On its own, a SIT Proflame 2 appliance runs from its Proflame remote. XV-IGN-PFAK lets home automation (Lutron, Crestron, Control4, Savant), a hearth remote receiver, or a wall switch run it instead.

A relay box between the X-VENTISO controller and the Proflame 2 ignition module. The appliance can light only after the controller proves draft. Factory-attached leads with lever nuts; plugs into a standard 120 V receptacle. Installation insert (PDF) (PDF, opens in a new tab)

XV-IGN-ADPT-RS Robertshaw ignition adapter cable with factory spade terminals.

XV-IGN-ADPT-RS Robertshaw Ignition Adapter

For appliances with a Robertshaw 780-715 U ignition control. Plugs into the X-VENTISO controller's black 4-pin ignition connection in place of the standard ignition cable, with factory spade terminals at the module: no splicing.

The appliance gets power to ignite only after the controller proves draft. Home automation, a hearth remote receiver, or a wall switch can make the call. Installation insert (PDF) (PDF, opens in a new tab)

Sold separately. Works with every X-VENTISO gas controller: GBC, GBC-DUO, Meridian, Meridian DUO and GFDC. On an XV-INTG system, it connects once, at the first unit's IGNITION. Dry contact only. Wiring: see the controller installation manual.

XV-VMASS-HTR

XV-VMASS-HTR Second Heater.

A second 2.0 kW duct heater for VMASS in cold climates. It mounts downstream of the first heater and connects to the VMASS controller by Molex, doubling the temperature rise at every airflow.

Sold separately. The second heater runs on its own dedicated 20 A, 120 V circuit.

XV-VMASS-HTR second duct heater, galvanized steel, with its 6 in. duct collar and heat sink.

Part no. XV-VMASS-HTR · Every VMASS has two Molex heater connections standard.

Downloads

Documents and Drawings.

Bring us the project. We'll find the yes.