How Houses Got Tight

Fifty years of energy code, and what it did to the air

Code cycle after code cycle since the 1970s, new houses have gotten tighter. That saves energy. It also changed how every chimney, range hood and fan in the house behaves.

The line that matters

Tested tight since 2012.

For most of the history of energy code, air sealing was a checklist item at most. The 2009 IECC offered a blower door test as an option, with a limit of 7 air changes per hour at 50 Pa. The 2012 IECC made the test required and cut the limit to 3 in most of the country, and the 2024 IECC cut it again in the warmest and coldest zones.

Chart: maximum air leakage allowed for a new house by IECC edition, 1995 to 2026. No air-leakage test before 2009. The 2009 IECC allowed 7 ACH50 if tested (optional). From the 2012 IECC, testing is required at 3 ACH50 in most of the U.S.; the warmest zones were 5 ACH50, then 4 from 2024; the coldest zones go to 2.5 in 2024. Passive House targets 0.6 ACH50. Milestones: 1998 first IECC, 2003 ASHRAE 62.2, 2009 IRC kitchen makeup air, 2012 blower door required, 2024 tighter again.
ACH50: air changes per hour at 50 Pa on a blower door test. Lower is tighter. Model code values; states adopt editions on their own schedules, often with amendments.

1970s

The energy crisis puts buildings on the map.

  • 1973

    • Oil embargo

    The oil embargo

    Energy prices surge. Heating and cooling buildings becomes a national issue.

  • 1975

    • EPCA
    • ASHRAE 90-75

    Federal energy law; ASHRAE 90-75

    Congress passes the Energy Policy and Conservation Act. ASHRAE publishes Standard 90-75, the first national standard for energy-conserving building design.

  • 1977

    • DOE

    U.S. Department of Energy

    Federal energy agencies, including the Federal Energy Administration, combine into the new Department of Energy.

  • 1978

    • Title 24, Part 6

    California energy standards

    California's Building Energy Efficiency Standards for new buildings take effect, making the state an early leader in building energy codes.

1980s and 1990s

One model code for the whole country.

  • 1983

    • MEC

    Model Energy Code

    The Council of American Building Officials publishes the Model Energy Code, a national baseline for energy-efficient homes.

  • 1992

    • EPAct
    • ENERGY STAR

    Energy Policy Act; ENERGY STAR

    Federal law has states review their residential codes against each new Model Energy Code edition. Separately, the EPA launches ENERGY STAR.

  • 1994

    • ICC

    International Code Council

    The three regional model code groups found the ICC: one body writing one family of model codes.

  • 1998

    • IECC

    The first IECC

    The Model Energy Code becomes the International Energy Conservation Code. A second edition follows in 2000, then a new one every three years.

2000s

Tight enough to need planned air.

  • 2003

    • ASHRAE 62.2

    Residential ventilation

    ASHRAE publishes its first residential ventilation standard.

    For the air in the house

    Fresh air now has to be designed in, not left to leaks.

  • 2009

    400CFM

    • IRC 2009

    Kitchen makeup air

    The International Residential Code requires makeup air for kitchen exhaust over 400 CFM.

    For the air in the house

    The code recognizes that a big range hood can pull a house negative.

  • 2009

    7ACH50, optional

    • IECC 2009

    Air leakage: test optional

    Builders show air sealing by visual inspection, or by a blower door test under 7 ACH50.

  • 2009

    $3.1BState grants

    • ARRA

    Codes for cash

    The stimulus ties state energy grants to codes. All 50 governors commit to 2009 IECC-level codes and 90 percent compliance in eight years. Not every state followed through on time, but the 2009 code becomes the national baseline.

2012 onward

Tested tight, every house.

  • 2012

    3ACH50, tested

    • IECC 2012

    Blower door test required

    Testing becomes mandatory: 3 ACH50 in climate zones 3 through 8, and 5 ACH50 in zones 1 and 2.

    For the air in the house

    In most of the country, a code-minimum house may now leak less than half the air the 2009 test limit allowed.

  • 2012

    < 5ACH50

    • IRC 2012

    Tight houses need mechanical ventilation

    A house that tests tighter than 5 ACH50 must have whole-house mechanical ventilation.

    For the air in the house

    The code itself says these houses can no longer breathe through their skin.

  • 2021

    5ACH50 cap

    • IECC 2021

    A limit on every path

    Performance and energy rating paths can trade some airtightness for other upgrades, but still have to test at 5 ACH50 or less.

  • 2024

    2.5–4ACH50

    • IECC 2024

    Tighter again

    4.0 ACH50 in the warmest zones, 3.0 in the middle of the country and 2.5 in the coldest, with credits for testing tighter still.

    For the air in the house

    The house keeps getting tighter. The range hood stays the same size.

  • Today

    0.6ACH50

    • Passive House

    High-performance programs

    Passive House targets 0.6 ACH50, about one-fifth of the 3 ACH50 code limit.

What it means

The house got tighter. The exhaust didn't get smaller.

A 400 CFM range hood moves the same air in a 2024 house as it did in a 1980 house. In the old house, most of that air came back through the cracks. In a code-tight house, it comes back through the easiest opening it can find, and in a house with a fireplace, that is often the chimney.

That is why draft and makeup air now have to be designed together, for the room they share.

Sources

Where these dates come from.

U.S. Department of Energy, Building Energy Codes Program (2009, 2012 and 2024 IECC air leakage). Federal Register, January 10, 2001 (Model Energy Code to IECC succession). California Energy Commission (Title 24, Part 6). ASHRAE (Standards 90-75 and 62.2-2003). Congressional Research Service (ENERGY STAR). Journal of Light Construction and Construction Dive (stimulus code commitments). International Code Council (IECC and IRC).

Model code dates shown. Each state adopts code editions on its own schedule, often with amendments. Confirm the edition in force with the authority having jurisdiction.